Diesel DC Generator 24V and 48V Battery Charging Generator
Designed for Hybrid Power Systems
The AGi4P-DC diesel DC generator is designed for reliable battery charging in hybrid power systems, telecom infrastructure, and off-grid energy systems. Powered by a Perkins 402F-05G two-cylinder diesel engine and paired with a Linz Electric DC alternator, this generator delivers regulated 24V or 48V DC output with extremely low ripple and adjustable current limiting.
Unlike high-speed air-cooled generators commonly used in telecom systems, the AGi4P-DC operates at 1800 RPM with liquid cooling, enabling quiet operation and continuous duty performance in demanding environments.
This makes it an ideal battery charging generator for solar hybrid systems, telecom power sites, and remote energy storage applications.
Key Features of the AGi4P-DC Diesel DC Generator
Continuous Duty Operation
Key design advantages include:
- Liquid-cooled Perkins diesel engine
Low 1800 RPM operation for durability and quiet performance
- Industrial generator design suitable for continuous operation
- Long service intervals and global Perkins parts support
These features make the generator suitable for remote installations where reliability is critical.
Direct DC Battery Charging
The AGi4P-DC produces regulated DC power directly, eliminating the need for external rectifiers or AC-to-DC conversion equipment.
Benefits include:
- Higher system efficiency
- Reduced electrical components
- Lower installation complexity
- Improved overall system reliability
Extremely Low Output Ripple
The Linz DC alternator produces less than 1% output ripple, even without batteries connected.
Benefits include:
- Cleaner charging current
- improved battery life
- stable operation for sensitive DC loads
This makes the generator suitable for telecom equipment, battery banks, and DC power systems.
Adjustable Voltage and Current Limiting
The generator includes integrated voltage regulation and current limiting capabilities.
This allows operators to:
- adjust charging voltage for different battery chemistries
- control charging current
- Protect battery banks from excessive charge rates
- integrate easily with hybrid energy systems
Quiet Low-RPM Diesel Operation
Many small generators operate at high speeds between 2800 and 3600 RPM.
The AGi4P-DC operates at 1800 RPM. This lower speed provides:
- Reduced noise levels
- Longer engine life
- Lower vibration
- Improved fuel efficiency
This makes it suitable for installations near sensitive environments such as telecom shelters and remote monitoring sites.
Technical Specifications
The AGi4P-DC diesel DC generator is built around a Perkins 402F-05G industrial diesel engine paired with a regulated low-voltage DC alternator system for battery charging and hybrid power applications. It is available in both 24V and 48V versions with adjustable voltage and built-in current limiting.
Engine Specifications
| Engine Model | Perkins 402F-05G |
|---|---|
| Engine Type | 2-cylinder industrial diesel engine |
| Displacement | 0.5 L |
| Rated Speed | 1800 RPM |
| Aspiration | Naturally aspirated |
| Cooling System | Liquid-cooled radiator system |
| Prime Mechanical Power | 3.3 kW net (4.4 hp) |
| Standby Mechanical Power | 3.6 kW net (4.8 hp) |
| Oil Capacity | 2.0 L |
| Coolant Capacity | 1.1 L |
| Starting System | Electric start |
| Service Interval | 500 hours |
DC Output Specifications
| Available Output Voltages | 24V DC or 48V DC |
|---|---|
| Voltage Adjustment | Adjustable output voltage |
| Current Limiting | Built-in current limiting |
| Output Regulation | Regulated DC output |
| Output Ripple | Less than 1% |
| Voltage Accuracy | ±0.5% |
| Operating Speed Range | Alternator designed for operation from 1300 to 2100 RPM |
| Maximum Current | Up to 200A on the 24V version |
| Alternator Efficiency | Greater than 84% |
| Protection Features | Thermal protection, over-excitation protection, and under-speed protection |
Control and Protection
| Controller Type | Auto-start controller |
|---|---|
| Automatic Start Capability | Yes |
| Instrumentation | Integrated instrumentation and system monitoring |
| Engine Protection | Automatic protection and shutdown functions |
| Application | Battery charging, hybrid power systems, telecom, and off-grid DC power systems |
Why These Specifications Matter
The AGi4P-DC combines low-speed 1800 RPM diesel operation, liquid cooling, regulated DC output, and built-in current limiting in one battery charging generator package. This gives you a cleaner and more durable solution for hybrid power systems than many high-speed air-cooled alternatives.
Designed for Hybrid Power Systems
The AGi4P-DC generator is designed to integrate into hybrid energy systems combining solar, batteries, and diesel generation.
Applications
Telecom Power Systems
The AGi4P-DC is ideal for powering telecom infrastructure, such as:
- cellular base stations
- communications towers
- remote telecom shelters
- Solar home backup
Solar Hybrid Energy Systems
The generator can be used as a battery charging generator in solar energy systems where reliable backup charging is required.
Typical installations include:
- off-grid solar power systems
- microgrids
- energy storage systems
Remote Industrial Power
The generator can provide reliable DC charging power for:
- pipleline monitoring systems
- remote instrumentation
- security and survillance installations
Why Use a DC Generator for Battery Charging
Traditional generators produce AC electricity that must be converted to DC using rectifiers before charging batteries.
Using a DC generator provides several advantages:
- higher charging efficiency
- fewer electronic components
- reduced system complexity
- improved long-term reliability
For these reasons, DC generators are commonly used in telecom power systems and hybrid energy installations.
Frequently Asked Questions
The AGi4P-DC is a diesel DC generator designed for battery charging and direct DC power applications. It is commonly used in hybrid power systems, telecom infrastructure, solar battery systems, and remote off-grid installations.
Yes. The AGi4P-DC is available in both 24V and 48V configurations to support a wide range of battery bank and DC power systems.
Yes. The generator includes adjustable voltage regulation so the output voltage can be set for the battery charging requirements of the system.
Yes. The generator includes built-in current limiting which helps protect battery banks and allows better control of the battery charging process.
The generator provides regulated DC output with less than 1% ripple. This makes it suitable for battery charging and sensitive DC system applications.
The AGi4P-DC uses a Perkins 402F-05G two-cylinder liquid-cooled diesel engine operating at 1800 RPM.
Yes. The liquid-cooled Perkins diesel engine and industrial design allow the generator to run continuously when required.
Liquid cooling improves thermal control and allows longer operating periods compared to small air-cooled engines.
Lower RPM operation reduces noise, vibration, and engine wear while improving long-term reliability.
Typical applications include telecom power systems, solar hybrid systems, remote monitoring stations, off-grid energy systems, and battery charging installations.
Why Use a DC Generator Instead of an AC Generator for Battery Charging?
A diesel DC generator is designed to produce direct current power for battery charging without requiring a separate AC-to-DC rectifier. In battery-based power systems, this can reduce complexity, improve efficiency, and lower the number of components in the charging system.
The AGi4P-DC diesel DC generator is built for hybrid power systems, telecom infrastructure, and off-grid battery charging applications where reliable DC output is required. With regulated voltage, built-in current limiting, low ripple output, and continuous-duty liquid-cooled operation, it is well suited for demanding charging applications.
Key Advantages of a DC Generator for Battery Charging
- Direct DC output for charging battery banks
- No separate rectifier required
- Lower system complexity
- Fewer electrical components to install and maintain
- High charging efficiency
- Clean regulated output with less than 1% ripple
- Adjustable voltage and built-in current limiting
DC Generator vs AC Generator for Battery Charging
| Feature | DC Generator | AC Generator |
|---|---|---|
| Battery Charging Output | Direct DC output | Requires rectifier or charger |
| System Complexity | Lower | Higher |
| Component Count | Fewer components | More components |
| Installation | Simpler for battery charging systems | More equipment required |
| Charging Efficiency | Typically higher for direct charging | Losses through conversion equipment |
| Best Use Case | Battery banks, telecom, hybrid systems | General AC loads and standard generator use |
Designed for Hybrid Power Systems
In hybrid energy systems, the generator is typically used to recharge batteries when solar input is low or battery voltage drops below a set threshold. Because the AGi4P-DC provides regulated DC output directly, it is a strong fit for battery-based systems that need dependable charging power without unnecessary conversion stages.
This makes the AGi4P-DC a practical solution for telecom towers, solar hybrid systems, remote monitoring stations, off-grid sites, and other installations where battery charging reliability matters.

