48 Volt DC Generator 14 kW | Perkins

From $14,341.32

Diesel engine powered DC Generator
Designed to charge batteries and provide power for off-grid DC systems.

• Industrial brushless alternator
• Adjustable voltage with Current Limiting
• Auto-start controller
• Perkins Engine Powered
• Large Fuel Tank
• Battery & Muffler
• Optional Weather Enclosure
• Linz Electric 48 Vdc Phase 9 Alternator

Add to Cart
Aurora AGi10P diesel DC generator
48 Volt DC Generator 14 kW | Perkins
From $14,341.32
Get Quote
Currency Switcher

Rating: 4.5 out of 5.
Shipping to USA and Canada
  • Insurance Included

48-Volt DC Generator – Purpose-Built for Telecom and Energy Storage

Efficient. Durable. Smart. Aurora’s DC diesel generator delivers ultra-clean, regulated power for critical battery systems, off-grid applications, and remote communications infrastructure.

  • Low-ripple 48 VDC output for sensitive electronics
  • Ideal for off-grid, telecom, and energy storage systems
  • Maintenance-free brushless alternator
  • Automatic two-wire start for hands-free operation
  • Extended runtime with optional 200-gallon fuel tank

Instrumentation, Protection & Control

At the core of this generator’s intelligence is the DynaGen TG350 controller—a rugged, feature-rich module engineered for demanding off-grid, telecom, and industrial applications. Built to withstand extreme temperatures, shock, and vibration, the TG350 delivers proven reliability in remote or unattended sites.

This controller provides complete system oversight, including real-time monitoring of engine performance, battery voltage, fuel level, and runtime hours. Its two-wire auto-start compatibility enables seamless coordination with inverters, charge controllers, and hybrid energy systems, making it ideal for automatic battery charging cycles.

The TG350 supports CANbus J1939 communication, allowing integration with modern diesel engines for advanced diagnostics, load management, and remote telemetry. This ensures compatibility with many third-party monitoring platforms and remote management tools. For installations requiring SCADA or building automation integration, an optional Modbus variant is also available.

Additional features include programmable warm-up, cool-down, and exercise cycles, as well as configurable warning alarms and automatic shutdowns for conditions such as low oil pressure, high engine temperature, or over/under voltage. Event logging and password-protected settings offer added security and make maintenance and troubleshooting fast and accurate.

With USB access and PC connectivity, configuration is simple using DynaGen’s free software—or changes can be made directly through the front-panel display. The TG350 significantly enhances operational control, system safety, and overall generator reliability in any mission-critical DC power installation.

Construction

Aurora Generators are engineered for long-term reliability in demanding environments. Every unit is built using high-quality materials and components that stand up to the challenges of outdoor, off-grid, and remote installations.

The enclosure and frame are constructed from galvanneal steel—a zinc-coated material that provides superior corrosion resistance and is ideal for outdoor use. To further enhance durability and aesthetics, all panels are finished with a UV-resistant, powder-coated finish that resists chipping, fading, and rust, even in harsh climates. For added protection, all fasteners are stainless steel, ensuring nothing corrodes or seizes over time.

To minimize vibration and extend component life, the generator is mounted with engineered vibration isolation mounts, which reduce mechanical stress on internal parts and connected structures. This not only improves reliability but also contributes to quieter operation.

The silenced exhaust system is tuned to reduce noise without sacrificing performance, making the generator suitable for both commercial and residential environments where sound levels must be kept low.

Access for maintenance is simple and secure. The panel doors are fully removable and lockable, allowing for quick service while keeping internal components protected from the elements and unauthorized access. These doors are mounted using tool-free lever latches for added convenience during inspection or repairs.

Aurora’s attention to structural detail results in a generator that is durable, low-maintenance, and built for years of dependable operation, even in remote and harsh conditions.

Additional information

Weight 950 kg
Brand

Perkins

Weather Enclosure

Include Weather Enclosure, No Weather Enclosure

Fuel Tank

No Fuel Tank, 12 Gallon Fuel Tank, 50 Gallon Fuel Tank (USA), 100 Gallon Fuel Tank (Canada), 100 Gallon Fuel Tank (USA)

Model

AGi20P-DC

Generator Type

Emergency Standby

Output Power

14 kW DC @ 48 Volts

Output Voltage

48 – 56 Vdc

Output Current

250 Amps Maximum

Perkins Engine

404D-22G

Linz Alternator Model

EMD2 48/250

DynaGen Controller

TG350

Specifications

Generator Specifications
MakeAurora
ModelAGi20P-48DC
Engine ModelPerkins 404D-22G
Alternator ModelLinz EMD2-48/250
Controller ModelDynaGen TG350
Voltage Range48 - 59 Vdc
Ripple<1% without battery
*Specifications are subject to change

Alternator Specifications
MakeLinz Electric
TypePhase 9 48 VDC
RPM1300 - 2100 RPM
ModelSMC4-48/250
Voltage Range48 - 59 Vdc
Current250 A
Power14 kW
Efficiency85.9
Weight295.42 lb
Ripple<1% without battery
*Specifications are subject to change

Engine Specifications
MakePerkins
Model404D-22G
Engine Power32.6 HP | 23.9 kWm
Cylinders4
RPM1800
Displacement2.216L
Aspiration Natural
Cycle4 Stroke
Combustion systemIndirect injection
Compression ratio23.3:1
RotationAnti-clockwise, viewed on flywheel
Total lubricating capacity10.6 litres
Cooling systemWater cooled
Total coolant capacity7.0 litres
Fuel Consumption
100% Prime Power
6.2 l/hr | 1.6 gal/hr
Fuel Consumption
50% Prime Power
3.5 l/hr | 0.82 gal/hr
Engine Specifications Brochure
*Specifications are subject to change

Generator Controller
FunctionInstrumentation, Protection & Control
MakeDynaGen
ModelTG350
Operating Voltage5.5 to 38VDC continuous. Cranking dropouts to 0VDC for 50mS, also meets SAE J1113-11
Standby Current60 mA @ 12 VDC
Protection• Reverse Battery Protected
• Surge & Load Dump SAE J1113-11
Operating Temperature• Controller Function: -40 to +70˚C
• Display Screen Viewing: -20 to +70˚C
Vibration & ShockMeets or exceeds SAE J1455
ElectromagneticMeets or exceeds MIL-STD-461E Conducted Emissions
Dimensions4.17"H x 6.5"W x 1.38"D
Weight0.83 lb
Speed SensingVIA J1939 buss, Magnetic pick-up or Generator
Inputs• AC Voltage Sensing (inputs for auto selection)
• Single Phase 2 and 3-wire
• Delta 3 and 4-wire
• Wye 2, 3 and 4-wire
• Max 600 vac* (direct connection)
true RMS, +/- 1% of full scale
Fixed Sensor Inputs0-7500Ω Engine Temperature sender
0-750Ω Senders or switches**
Universal Sensor Inputs (Pressure, Temperature, Level, Volts or Amps.):
*for 600vac systems use a step-down transformer or centre tap.
0-7500Ω Senders, 4-20ma, 0-5V or switch**
0-750Ω Senders
Configurable Switched Inputs• Programmable text
• Auto detect close to +Battery or Ground
Electronic Engine SupportStandard J1939 Engines (Tier II, III & IV)
Output (Includes fuel & crank)Switched Outputs - 1 AMP Max UL pilot duty
Switched to +Battery
Short circuit & overload protected
Communications• SAE J1939
• Tier 2,3, and 4 engines
• Address settings for both the controller and the engine ECM
• USB
• PC Configurator Connection
• High retention socket accepts standard
• USB cable
• RTU slave mode
• RS 485 port (9600, 19200, 38400,57600 baud)
• Galvanic isolation

Downloads

Generator AGi20P-DC Downloads
AGi20P-DC Specifications PDF
AGi20P-DC-E 3D CAD PDF (with standard fuel tank)
AGi20P-DC-E-50 3D CAD PDF (with 50 gallon fuel tank)
AGi20P-DC-E-100 3D CAD PDF (with 100 gallon fuel tank)

Alternator EMD2 48/250
Linz Alternator Phase 9 Manual
Linz Alternator Brochure
Linz Alternator Wiring Diagram

Generator Controller
DynaGen Controller TG350DynaGen Controller TG410
DynaGen TG350 SpecificationsDynaGen TG410 Specifications
DynaGen TG350 User ManualDynaGen TG410 User Manual
Dynagen AccessoriesDynagen Accessories
DynaGen Rapidcore Software User ManualDynaGen Rapidcore Software User Manual
Rapidcore Software DownloadRapidcore Software Download
DynaGen TG350 Firmware 1.94.03DynaGen TG410 Firmware 1.94.03
DynaGen J1939 Reference ManuelDynaGen J1939 Reference Manuel
DynaGen Wiring Harness GuideDynaGen Wiring Harness Guide
DynaGen Modbus Reference Manual

Perkins Engine 404D-22G Downloads
Perkins 404D-22G Specification Brochure | PN1912B
Perkins 404D-22G Engine Specifications | KENR6223-03
Perkins Operation and Maintenance Manual | SEBU8311-10
Perkins 404D-22TG Fluid Recommendations | M0113102-04
Perkins Systems Operation Testing and Adjusting | KENR6225-03
Perkins 404D-22G Disassembly and Assembly Manual | KENR6226-10