40 kW Perkins Diesel Generator

From $21,197.00

  • Perkins Engine Powered
  • EPA Tier 4 (no DEF)
  • Standby, Prime or Continuous Power
  • Single or Three Phase Power Options
  • Multiple fuel tank options
  • Advanced instrumentation and control
  • Power-coated sound attenuated enclosure.
Add to Cart
40 kW Hatz Diesel Engine powered generator.
40 kW Perkins Diesel Generator
From $21,197.00
Options & Accessories
Get Quote
Currency Switcher

Rating: 4.5 out of 5.
Shipping to USA and Canada
  • Insurance Included

Aurora Commercial Diesel Generators: Built for the Long Haul

When uptime matters, Aurora delivers. Our commercial diesel generators are engineered for harsh-climate reliability, clean electrical performance, and easy service, so your operation keeps moving when the grid doesn’t.

  • Industrial-grade power: 1800 RPM diesel platforms deliver low noise, excellent fuel economy, and long engine life.
  • Clean, stable electricity: Brushless, AVR-regulated 4-pole alternators protect sensitive electronics and start motors with confidence.
  • Your voltage, your way: Single-phase 120/240 V, or three-phase 120/208, 277/480, and 600 V options to match your building’s distribution.
  • Serious runtime: Built-in day tank standard, with optional sub-base tanks or separate 100/200-gal fuel tanks for extended operation.
  • Integration-ready: Two-wire auto-start and ATS compatibility streamline installation with any two-wire compatible transfer switch.
  • Service made simple: Thoughtful “cold-side” access, long service intervals, and widely available parts reduce downtime and cost.
  • Weather-tough enclosures: Open skid or sound-attenuated canopies designed for Canadian winters and year-round outdoor duty.
  • Compliance-minded: Built with UL/CSA-recognized components, ready for code-compliant installation by licensed electricians.

Why Aurora? Because we focus on the total cost of ownership, not just the first price. From premium components to expert support, our generators deliver dependable power, year after year.

Let’s power your facility. Tell us your load profile, preferred voltage, and runtime goals, and an Aurora power specialist will configure the right commercial generator for your site.

Aurora Generators - Weather enclosure exploded view

Weather Enclosures:

Aurora enclosures, factory-installed for seamless integration, enhance the performance, security, and safety of their corresponding generator sets while providing reliable protection against harsh weather conditions. Constructed from durable galvannealed steel and secured with stainless steel fasteners, these enclosures offer superior corrosion resistance for long-lasting durability. Lift-off doors and access panels ensure effortless access for routine maintenance and service, making upkeep more convenient and efficient.

Aurora Generators - base frame and fuel tank exploded view

Construction

Aurora Generators are built to withstand the toughest conditions. Featuring heavy-gauge steel frames and fuel tanks, each unit is powder-coated for superior corrosion resistance. To ensure long-term durability, only stainless steel fasteners are used in assembly, preventing rust and wear over time.

Powered by Perkins

Perkins engines are built to perform in demanding conditions, delivering reliable power for extended runtimes. With an expected lifespan exceeding 20,000 hours, they provide long-term dependability for critical applications. As a subsidiary of Caterpillar—a globally respected leader in power solutions—Perkins offers exceptional warranties and industry-leading product support, ensuring peace of mind for every owner.

ECP28 Meccalte Alternator

Generator Head

Aurora Generators use Mecc Alte brushless and voltage-regulated alternators. They feature overload capability up to 300% for 20 seconds and maintain a voltage regulation of +/- 1%, ensuring stable and consistent power output.

DynaGen TG410 TG350

Protection, Monitoring and Control

This 40 kW Perkins Diesel Generator is equipped with a DynaGen TG350 controller. The controller is designed to meet military specifications and is renowned for its ruggedness and ability to operate reliably in demanding environments.

Service Kits

Low Maintenance

Diesel generators have lower maintenance requirements compared to other types of generators. Specifically, the oil and filter only need to be changed every 500 hours of operation instead of every 100 hours for non-diesel generators. Aurora also carries a wide selection of parts and accessories for your generator.

Aurora Support Staff

Lifetime Customer Support

Enjoy free lifetime customer support with every purchase. No matter when you need assistance, Aurora’s dedicated customer support team will be there to help you.

5 Year Warranty on Aurora Generators

Flexible Warranty

The Aurora 15 kW Perkins Diesel Generator comes with a 5-year comprehensive factory warranty. Extended warranties are also available.

Fuel Nozzle

Cost Effective

A diesel-powered generator can save over $100.00 in fuel per day when used to power a home, compared to natural gas, propane, or gasoline. This is because diesel fuel has a higher energy density than other fuels, meaning less fuel is required to generate the same amount of power. For example, a typical home would use 0.5 gallons of diesel an hour, while it would need 4-6 gallons of propane to generate the same amount of power.

Diesel Fuel Tanks

Fuel Tank Options

This generator comes with a standard 50-gallon fuel tank. However, for those needing extended runtimes, larger fuel tanks are available, including both sub-base and standalone options.

Additional information

Weight 700 kg
Brand

Perkins

Weather Enclosure

Include Weather Enclosure, No Weather Enclosure

Fuel Tank

No Fuel Tank, 12 Gallon Fuel Tank, 50 Gallon Fuel Tank (USA), 100 Gallon Fuel Tank (Canada), 100 Gallon Fuel Tank (USA)

Downloads

Engine Manuals
Perkins 404J-E22T Specifications
Perkins M0094137-04 404J-E22T Operations & Maintenance Manual

Generator Controller
DynaGen Controller TG350DynaGen Controller TG410
DynaGen TG350 SpecificationsDynaGen TG410 Specifications
DynaGen TG350 User ManualDynaGen TG410 User Manual
Dynagen AccessoriesDynagen Accessories
DynaGen Rapidcore Software User ManualDynaGen Rapidcore Software User Manual
Rapidcore Software DownloadRapidcore Software Download
DynaGen TG350 Firmware 1.94.03DynaGen TG410 Firmware 1.94.03
DynaGen J1939 Reference ManuelDynaGen J1939 Reference Manuel
DynaGen Wiring Harness GuideDynaGen Wiring Harness Guide
DynaGen Modbus Reference Manual

Specifications

ManufacturePerkins
Model403J-E17T
Cylinders3
RPM1800
TypeTurbocharged Diesel
Combustion SystemDirect Injection
Displacement1.662L
101 cu in
Power 40.23 hp
30 kWm
25 kWe
EmissionsUS EPA Tier 4f
(Uses DPF filter - NO DEF required)
Starter (v)12
Alternator150 Amp
Weight (wet)525 lbs
238 kG

Controller Specifications
MakeDynaGenDynaGen
ModelTG350TG410
Aurora GeneratorsStandardOptional
Controller Function -40 to +70˚C
-40 to +174˚F
-40 to +70˚C
-40 to +174˚F
ElectromagneticMeets or exceeds MIL-STD-461E
Conducted Emissions
Meets or exceeds MIL-STD-461E
Conducted Emissions
Display
Oil PressureYesYes
Engine TemperatureYesYes
Fuel LevelYesYes
Hour MeterYesYes
RPMYesYes
Real time clock with time/dateYesYes
Battery VoltageYesYes
AC VoltageYesYes
AC CurrentNoYes
(With optional CTs)
Modbus Connectivity NoYes
Maintenance counterYesYes
Auto start on Low BatteryYesYes
Two-Wire Auto StartYesYes
Manual StartYesYes
Exerciser ClockYesYes
150 Event LogYesYes
Passcode protectedYesYes
Automatic shutdowns and warningsYesYes
Pre-heat and many configurable timersYesYes
Warranty5-Year / 17,500 hour warranty5-Year / 17,500 hour warranty

Reviews