I can just barely hear the unit running inside the house
From John G – AK USA
I decided to locate the generator on a pad that formerly housed a covered hot tub. The location was perfect for this purpose, as it was close to my fuel source for the garage and transfer switch in the same.
The piping is 1/2” black pipe for supply and returns with Firomatic safety valve and check valve, plumbed to a dedicated generator/ Bobcat fueling tank of 300 gallons to provide fuel turnover.
I debated on removing the feet to place the unit directly on the slab but, chose to leave it elevated to facilitate the electrical and fuel piping. I installed a 2” schedule 40 PVC conduit for 2/0 carriers and 1/0 neutral to the transfer switch and a separate 1/2” PVC conduit for the start/stop signal wires from the transfer switch to eliminate any possible interference.
I also ran dedicated circuits for the hot start heater, oil pan heater and battery charger on GFCI outlets.
I am also happy to report, I can just barely hear the unit running inside the house and less than 68 decibels at the front door approximately 40’ away. I know I made the right choice with purchasing an Aurora generator, thanks for making a quality product.